The 625F01TCEEU Heated (100°C) Absolute Baratron® Capacitance Manometer with Trip Points features 1 Torr full scale pressure measurement, a female 8 VCR type fitting, and a terminal block adaptor electrical connector. It has two user adjustable process trip point relays, each with an adjustment range from 0.1% to 100% of Full Scale or voltage equivalent 0.01 to 10 VDC. Dual color LEDs indicate relay status. Typical relay uses include pump cross-over and valve activation. The 625F operates with ±15 VDC (±5%) input at <600 mA, and provides an output of 0 to 10 VDC linear with pressure. The 625F sensor exposes only Inconel® to the process permitting the use with corrosive or dirty gases. Measurements are independent of gas composition. The modern stainless steel enclosure provides a cleanroom compatible product.
Technical Specs
Type
Vacuum Pressure Transducer
Sensor Type
Capacitance Manometer
Measurement Type
Absolute
Sensor Temperature
100°C
Full Scale Range
1 Torr
Fitting Type
8 VCR female
Analog Output
0 - 10 VDC
Analog Connector
Terminal Block Adaptor
Accuracy
0.25% of Reading
Resolution
0.001% of Full Scale
Zero Temperature Coefficient
0.002% of Full Scale/°C
Span Temperature Coefficient
0.02% of Reading/°C
Operating Temperature Range
15° to 50°C
Volume
6.3 cc
Warm-up Time
2 hours
Overpressure Limit
45 psia (310 kPa)
Exposed Materials
Inconel
Power Requirements
±15 VDC ±5% @ 0.60 Amps (max.)
Trip Points
2
Trip Point Level Signal
0.01 to 10 VDC for each trip point
Relay Contact Ratings
SPDT, 1 Amp @ 30 VDC or 0.5 Amp @ 30 VAC resistive
Compliance
CE
Technical Specs
Type
Vacuum Pressure Transducer
Sensor Type
Capacitance Manometer
Measurement Type
Absolute
Sensor Temperature
100°C
Full Scale Range
1 Torr
Fitting Type
8 VCR female
Analog Output
0 - 10 VDC
Analog Connector
Terminal Block Adaptor
Accuracy
0.25% of Reading
Resolution
0.001% of Full Scale
Zero Temperature Coefficient
0.002% of Full Scale/°C
Span Temperature Coefficient
0.02% of Reading/°C
Operating Temperature Range
15° to 50°C
Volume
6.3 cc
Warm-up Time
2 hours
Overpressure Limit
45 psia (310 kPa)
Exposed Materials
Inconel
Power Requirements
±15 VDC ±5% @ 0.60 Amps (max.)
Trip Points
2
Trip Point Level Signal
0.01 to 10 VDC for each trip point
Relay Contact Ratings
SPDT, 1 Amp @ 30 VDC or 0.5 Amp @ 30 VAC resistive
Compliance
CE
Additional CAD file downloads are not available for this product.
Enter your email address below to reset your account password.
Provide an order number and postal code to quickly check the status of an order.Login to view your complete order history.
To access this and other valuable technical resources, please sign in or register for a new online account.
Also available on Newport.com
VAT ID has invalid format. It will not be saved with the order when submitted.
Heated Capacitance Manometer, 1 Torr, 100°C, 8 VCR-F, Terminal Block, 0-10 VDC, 2 Relays
Heated Capacitance Manometer, 1 Torr, 100°C, 8 VCR-F, Terminal Block, 0-10 VDC, 2 Relays