$______________________________________________________________$ $ CDN367 Electronic Data Sheet $ $ ---------------------------- $ $ EDS revision 1.10 for use with the rev 2.06 version of the $ $ CDN367 $ $ (class-1, inst-1, attr-4) $ $ $ $ $ $ $ Once the CDN367 has been configured for communication with $ $ a serial device, the DeviceNet masters's Produce and $ $ Consume settings should be set to match the Produce Size $ $ and Consume Size settings of the Serial Stream Object group $ $ in order to establish a polled connection. $ $ $ $ Attributes of variable data type, namely the Rx and Tx Data $ $ attributes (cls-65/66, inst-1, attr-3) and attributes that $ $ use the SHORT_STRING type (Pre-Dilimiter, Post_Dilimiter $ $ Pre-String, Post-String, String1, String2) cannot be read $ $ or configured through this file. Explict messaging $ $ interface such as Allen Bradly's Class Instance Editor $ $ must be used to read and configure these attributes. $ $______________________________________________________________$ $ Advanced DeviceNet Monitor Electronic Data Sheet $ Complies with EDSChecker Version 1.31 (Intermediary) [File] DescText= "DeviceNet Network"; CreateDate= 08-09-2007; CreateTime= 04:31:48; ModDate= 08-09-2007; ModTime= 12:00:00; Revision= 1.10; $EDS File Revision [Device] VendCode= 59; $Identity Object Inst 1, Attr 1 ProdType= 12; $Identity Object Inst 1, Attr 2 ProdCode= 5872; $Identity Object Inst 1, Attr 3 MajRev= 2; $Identity Object Inst 1, Attr 4 (high byte) MinRev= 6; $Identity Object Inst 1, Attr 4 (low byte) VendName= "D.I.P. Inc."; ProdTypeStr="Communications Adapter"; ProdName= "CDN367-01"; $Identity Object Inst 1, Attr 7 Catalog= "Adv. RS485 Gateway"; [IO_Info] Default= 0x0001; PollInfo= 0x0001,0,0; [ParamClass] MaxInst=171; $171 parameters Descriptor=9; $Supports instancese, full attributs, and $ must do non­volatile storage save command CfgAssembly=0; $No configuration assembly [Params] $______________________________________________________________$ $ Parameter Format $ $______________________________________________________________$ $ $ Param1= $ Attribute 3 $ 0, $ parameter value slot $ 6, "20 40 24 01 30 03", $ link size and path $ 0x01, $ descriptor $ 9, 4, $ data type, 4 byte(s) $ "Baud Rate", $ parameter name $ "bits per second", $ units string $ "Baud Rate for RS485 channel", $ help string $ 0,57600,19200, $min, max, default $ 1,1,1,0,0,0,0,0,0; $mult, div, base, offset, scaling and links $ $ Parameter value slot: This is always equal to 0. $ $ Link size and path: Maps the parameter to a specific device attribute. $ Format: number of bytes in path, "path" $ path: "20 (class number) 24 (instance number) 30 (attribute number)" $ $ Example: 6, "20 40 24 01 30 04" = $ class 0x40, instance 0x01, attribute 0x04 $ $ $ Data type: Parameter data type value, size in bytes $ $ Type Value Size $ UINT 2 2 $ INT 3 2 $ BOOL 4 1 $ SINT 5 1 $ USINT 8 1 $ REAL 11 4 $ BYTE 24 1 $ $ Note BYTE is used for USINT device values that have $ each bit enumerated. $ $ $ $ $ Descriptor: 1 byte value describing the parameters behavior $ $ Bit Meaning $ 0 Parameter can be set $ 1 Supports enumeration (i.e. set with pull down menus) $ 2 Supports scaling (change of units) $ 3 Scaling information is supported by other parameters $ 4 Parameter is read only $ 5 Parameter is activly updated by its device $ 6 Supports extended precision scaling $ $ Note that scaling is not used in this configuration file. $ $ Min, max, default: Sets the minimum, maximum values the parameter can have $ and the defualt value set by the EDS file. $ $ Units: Descriptive string that indicates the units for the paramerter if $ applicable. $ $ Help string: Gives a description of the parameter's function $ $ Mult, div, base, offset, scaling and links: $ $ Provides parameter scaling information. Since scaling is not used in $ This configuration file, these are always set to $ "1,1,1,0,0,0,0,0,0". $ $_______________________________________________________________$ $ User Defined Serial Stream Object Class 64(0x40) $ $ Instance 1 $ $_______________________________________________________________$ Param1= $ Attribute 3 0, $ parameter value slot 6, "20 40 24 01 30 03", $ link size and path 0x01, $ descriptor 9, 4, $ data type, 4 byte(s) "Baud Rate", $ parameter name "bits per second", $ units string "Baud Rate for RS485 channel \nCommon Baud Rates\n\n\t300\n\t600\n\t1200\n\t2400\n\t4800\n\t9600\n\t19200\n\t38400\n\t57600", $ help string 0,57600,19200, 1,1,1,0,0,0,0,0,0; Param2= $ Attribute 4 0, $ parameter value slot 6, "20 40 24 01 30 04", $ link size and path 0x03, $ descriptor 8, 1, $ data type, 1 byte(s) "Data Bits", $ parameter name "", $ units string "Specifies the number of Data bits (7 or 8)", 7,8,8, 1,1,1,0,0,0,0,0,0; Param3= $ Attribute 5 0, $ parameter value slot 6, "20 40 24 01 30 05", $ link size and path 0x03, $ descriptor 8, 1, $ data type, 1 byte(s) "Parity", $ parameter name "", $ units string "Parity on RS485 channel.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param4= $ Attribute 6 0, $ parameter value slot 6, "20 40 24 01 30 06", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "Stop Bits", $ parameter name "", $ units string "Number of Stop Bits terminating a serial character", 1,2,1, 1,1,1,0,0,0,0,0,0; Param5= $ Attribute 7 0, $ parameter value slot 6, "20 40 24 01 30 07", $ link size and path 0x03, $ descriptor 8, 1, $ data type, 1 byte(s) "Flow Control", $ parameter name "", $ units string "Flow Control on RS485 channel.", 0,2,0, 1,1,1,0,0,0,0,0,0; Param6= $ Attribute 10 0, $ parameter value slot 6, "20 40 24 01 30 0A", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "Delimiter Mode", $ parameter name "", $ units string "Bit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tReserved\tReserved\tLength\tTimeout\tList", 0,6,4, 1,1,1,0,0,0,0,0,0; Param7= $ Attribute 13 0, $ parameter value slot 6, "20 40 24 01 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "Timeout", $ parameter name "ms", $ units string "Sets max timeout in milliseconds between bytes that the unit uses to determine when a packet is complete", 0,255,255, 1,1,1,0,0,0,0,0,0; Param8= $ Attribute 14 0, $ parameter value slot 6, "20 40 24 01 30 0E", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "Packet Length", $ parameter name "bytes", $ units string "Specifies the number of bytes to wait for before determining packet is complete.", 0,255,16, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 1 $ $_______________________________________________________________$ Param9= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 01 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-1) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param10= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 01 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-1) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param11= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 01 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-1) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param12= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 01 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-1) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list)..", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param13= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 01 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-1) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param14= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 01 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-1) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param15= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 01 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-1) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,1, 1,1,1,0,0,0,0,0,0; Param16= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 01 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-1) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet " "to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,1, 1,1,1,0,0,0,0,0,0; Param17= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 01 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-1) Sync Enabled", $ parameter name "", $ units string "When set the unit will not respond with new data until the" "value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 2 $ $_______________________________________________________________$ Param18= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 02 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-2) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param19= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 02 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-2) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param20= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 02 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-2) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param21= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 02 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-2) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list)..", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param22= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 02 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-2) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param23= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 02 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-2) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param24= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 02 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-2) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,1,0,0,0,0,0,0; Param25= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 02 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-2) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param26= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 02 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-2) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 3 $ $_______________________________________________________________$ Param27= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 03 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-3) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param28= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 03 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-3) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param29= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 03 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-3) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param30= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 03 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-3) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param31= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 03 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-3) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param32= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 03 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-3) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param33= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 03 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-3) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,1,0,0,0,0,0,0; Param34= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 03 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-3) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param35= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 03 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-3) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 4 $ $_______________________________________________________________$ Param36= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 04 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-4) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param37= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 04 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-4) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param38= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 04 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-4) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param39= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 04 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-4) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2\n INT = 0xC3\n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param40= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 04 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-4) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param41= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 04 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-4) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param42= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 04 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-4) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,0,0,0,0,0,0,0; Param43= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 04 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-4) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param44= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 04 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-4) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 5 $ $_______________________________________________________________$ Param45= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 05 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-5) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param46= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 05 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-5) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param47= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 05 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-5) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param48= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 05 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-5) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param49= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 05 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-5) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param50= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 05 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-5) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param51= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 05 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-5) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,1,0,0,0,0,0,0; Param52= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 05 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-5) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param53= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 05 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-5) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $Serial Receive Object Class 65(0x41) $ $Instance 6 $ $_______________________________________________________________$ Param54= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 06 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-6) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param55= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 06 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-6) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param56= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 06 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-6) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param57= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 06 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-6) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param58= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 06 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-6) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param59= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 06 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-6) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param60= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 06 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-6) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,1,0,0,0,0,0,0; Param61= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 06 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-6) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param62= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 06 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-6) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $Serial Receive Object Class 65(0x41) $ $Instance 7 $ $_______________________________________________________________$ Param63= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 07 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-7) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param64= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 07 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-7) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param65= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 07 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-7) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param66= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 07 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-7) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param67= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 07 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-7) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param68= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 07 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-7) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param69= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 07 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-7) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,1,0,0,0,0,0,0; Param70= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 07 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-7) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param71= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 07 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-7) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $Serial Receive Object Class 65(0x41) $ $Instance 8 $ $_______________________________________________________________$ Param72= $ Attrib 4 0, $ parameter value slot 6, "20 41 24 08 30 04", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-8) Receive Toggle", $ parameter name "", $ units string "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param73= $ Attrib 5 0, $ parameter value slot 6, "20 41 24 08 30 05", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-8) Receive Acknowledge", $ parameter name "", $ units string "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param74= $ Attrib 6 0, $ parameter value slot 6, "20 41 24 08 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Rx Inst-8) Receive Mode", $ parameter name "", $ units string "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0,7,1, 1,1,1,0,0,0,0,0,0; Param75= $ Attrib 9 0, $ parameter value slot 6, "20 41 24 08 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-8) Data Type", $ parameter name "", $ units string "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param76= $ Attrib 10 0, $ parameter value slot 6, "20 41 24 08 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-8) Data Size", $ parameter name "bytes", $ units string "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1,255,17, 1,1,1,0,0,0,0,0,0; Param77= $ Attrib 13 0, $ parameter value slot 6, "20 41 24 08 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-8) Conversion Type", $ parameter name "", $ units string "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0,255,0, 1,1,1,0,0,0,0,0,0; Param78= $ Attrib 15 0, $ parameter value slot 6, "20 41 24 08 30 F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-8) Data in Poll Response", $ parameter name "", $ units string "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0,1,0, 1,1,1,0,0,0,0,0,0; Param79= $ Attrib 16 0, $ parameter value slot 6, "20 41 24 08 30 10", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-8) Enabled", $ parameter name "", $ units string "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param80= $ Attrib 17 0, $ parameter value slot 6, "20 41 24 08 30 11", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Rx Inst-8) Sync Enabled", $ parameter name "", $ units string "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 1 $ $_______________________________________________________________$ Param81= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 01 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-1) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 1 data. Mapped to bit 0 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param82= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 01 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-1) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param83= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 01 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-1) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param84= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 01 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-1) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param85= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 01 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-1) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param86= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 01 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-1) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param87= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 01 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-1) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param88= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 01 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-1) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param89= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 01 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-1) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,1, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 2 $ $_______________________________________________________________$ Param90= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 02 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-2) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 2 data. Mapped to bit 1 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param91= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 02 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-2) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param92= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 02 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-2) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param93= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 02 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-2) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param94= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 02 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-2) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param95= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 02 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-2) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param96= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 02 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-2) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param97= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 02 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-2) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param98= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 02 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-2) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 3 $ $_______________________________________________________________$ Param99= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 03 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-3) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 3 data. Mapped to bit 2 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param100= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 03 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-3) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param101= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 03 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-3) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param102= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 03 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-3) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param103= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 03 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-3) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param104= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 03 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-3) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param105= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 03 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-3) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param106= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 03 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-3) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param107= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 03 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-3) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 4 $ $_______________________________________________________________$ Param108= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 04 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-4) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 4 data. Mapped to bit 3 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param109= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 04 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-4) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param110= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 04 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-4) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param111= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 04 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-4) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param112= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 04 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-4) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param113= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 04 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-4) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param114= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 04 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-4) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param115= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 04 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-4) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param116= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 04 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-4) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 5 $ $_______________________________________________________________$ Param117= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 05 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-5) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 5 data. Mapped to bit 4 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param118= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 05 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-5) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param119= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 05 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-5) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param120= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 05 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-5) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param121= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 05 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-5) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param122= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 05 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-5) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param123= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 05 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-5) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param124= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 05 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-5) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param125= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 05 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-5) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 6 $ $_______________________________________________________________$ Param126= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 06 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-6) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 6 data. Mapped to bit 5 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param127= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 06 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-6) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param128= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 06 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-6) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param129= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 06 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-6) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param130= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 06 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-6) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param131= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 06 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-6) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param132= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 06 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-6) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param133= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 06 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-6) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param134= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 06 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-6) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 7 $ $_______________________________________________________________$ Param135= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 07 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-7) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 7 data. Mapped to bit 6 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param136= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 07 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-7) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param137= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 07 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-7) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param138= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 07 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-7) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param139= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 07 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-7) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param140= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 07 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-7) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param141= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 07 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-7) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param142= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 07 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-7) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param143= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 07 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-7) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 8 $ $_______________________________________________________________$ Param144= $ Attrib 4 0, $ parameter value slot 6, "20 42 24 08 30 04", $ link size and path 0x01, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-8) Transmit Toggle",$ parameter name "", $ units string "Toggled to transmit new Instance 8 data. Mapped to bit 7 of the [TxToggle1-8] byte in the poll command.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param145= $ Attrib 5 0, $ parameter value slot 6, "20 42 24 08 30 05", $ link size and path 0x30, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-8) Transmit Acknowledge", $ parameter name "", $ units string "Toggles when transmit from previous poll command is complete.", 0,1,0, 1,1,1,0,0,0,0,0,0; Param146= $ Attrib 6 0, $ parameter value slot 6, "20 42 24 08 30 06", $ link size and path 0x03, $ descriptor 24, 1, $ data type, 1 byte(s) "(Tx Inst-8) Transmit Mode", $ parameter name "", $ units string "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0,0x1F,0x01, 1,1,1,0,0,0,0,0,0; Param147= $ Attrib 9 0, $ parameter value slot 6, "20 42 24 08 30 09", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-8) Data Type ", $ parameter name "", $ units string "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN367 must be taken out of the scan list).", 0xC2,0xDA,0xDA, 1,1,1,0,0,0,0,0,0; Param148= $ Attrib 10 0, $ parameter value slot 6, "20 42 24 08 30 0A", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-8) Data Size", $ parameter name "", $ units string "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN367 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0,255,17, 1,1,1,0,0,0,0,0,0; Param149= $ Attrib 11 0, $ parameter value slot 6, "20 42 24 08 30 0B", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-8) Width ", $ parameter name "", $ units string "Sets the field width for the instance data.", 0,255,16, 1,1,1,0,0,0,0,0,0; Param150= $ Attrib 12 0, $ parameter value slot 6, "20 42 24 08 30 0C", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-8) Precision ", $ parameter name "", $ units string "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0,4,0, 1,1,1,0,0,0,0,0,0; Param151= $ Attrib 13 0, $ parameter value slot 6, "20 42 24 08 30 0D", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Tx Inst-8) Conversion Type", $ parameter name "", $ units string "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0,0xFF,0, 1,1,1,0,0,0,0,0,0; Param152= $ Attrib 15 0, $ parameter value slot 6, "20 42 24 08 30 0F", $ link size and path 0x03, $ descriptor 4, 1, $ data type, 1 byte(s) "(Tx Inst-8) Data in Poll Command", $ parameter name "", $ units string "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN367 must not be in the scan list).", 0,1,0, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ User Defined Serial Stream Object Class 64(0x40) $ $ Instance 1 -- Extended Attributes $ $_______________________________________________________________$ Param153= $ Attribute 15 0, $ parameter value slot 6, "20 40 24 01 30 0F", $ link size and path 0x23, $ descriptor 24, 1, $ data type, 1 byte(s) "Serial Status", $ parameter name "", $ units string "Indicates the occurance of a parity error or fifo overrun. Setting this value resets the error status. \n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nReserved\tReserved\tTx Parity\tTx Fifo\tReserved\tReserved\tRX Parity\tRx Fifo\n\t\tError\tOverrun\t\tError\tOverrun", 0,255,0, 1,1,1,0,0,0,0,0,0; Param154= $ Attribute 20 0, $ parameter value slot 6, "20 40 24 01 30 14", $ link size and path 0x30, $ descriptor 2, 2, $ data type, 2 byte(s) "Poll Produce Size", $ parameter name "", $ units string "The size of the poll response once a polled connection is established", 0,0xFFFF,19, 1,1,1,0,0,0,0,0,0; Param155= $ Attribute 21 0, $ parameter value slot 6, "20 40 24 01 30 15", $ link size and path 0x30, $ descriptor 2, 2, $ data type, 2 byte(s) "Poll Consume Size", $ parameter name "", $ units string "The size of the poll command once a polled connection is established", 0,0xFFFF,19, 1,1,1,0,0,0,0,0,0; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Class 65 Width attribute $ $_______________________________________________________________$ Param156= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 01 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-1) Width", $ parameter name "", $ units string "The maximum number of recieved rs485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param157= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 02 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-2) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param158= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 03 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-3) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param159= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 04 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-4) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param160= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 05 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-5) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param161= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 06 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-6) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param162= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 07 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-7) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param163= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 08 30 0b", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-8) Width", $ parameter name "", $ units string "The maximum number of recieved RS485 bytes the CDN367 will convert for this instance. Any data recieved past width will be truncated. ", 1,0xFF,1, 1,1,1,0,0,0,0,0,0; Param164= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 01 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-1) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param165= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 02 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-2) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param166= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 03 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-3) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param167= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 04 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-4) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param168= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 05 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-5) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param169= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 06 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-6) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param170= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 07 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-7) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; Param171= $ Attribute 11 0, $ parameter value slot 6, "20 41 24 08 30 0e", $ link size and path 0x01, $ descriptor 8, 1, $ data type, 1 byte(s) "(Rx Inst-8) Padding Char.", $ parameter name "", $ units string "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0,0xFF,00, 1,1,1,0,0,0,0,0,0; [EnumPar] $_______________________________________________________________$ $ User Defined Serial Stream Object Class 64(0x40) $ $ Instance 1 $ $_______________________________________________________________$ Param2= "7 Data Bits", "8 Data Bits"; Param3= "None","Odd","Even","Mark","Space"; Param5= "None","XON/XOFF","CTS/RTS"; Param6= "List", "Timeout", "Length"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 1 $ $_______________________________________________________________$ Param11= "Use Data", "Use Pre-String", "Use Post-String"; Param15= "Not in Poll","Data in Poll"; Param16= "Ignore this instance","Search receive string"; Param17= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 2 $ $_______________________________________________________________$ Param20= "Use Data", "Use Pre-String", "Use Post-String"; Param24= "Not in Poll","Data in Poll"; Param25= "Ignore this instance","Search receive string"; Param26= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 3 $ $_______________________________________________________________$ Param29= "Use Data", "Use Pre-String", "Use Post-String"; Param33= "Not in Poll","Data in Poll"; Param34= "Ignore this instance","Search receive string"; Param35= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 4 $ $_______________________________________________________________$ Param38= "Use Data", "Use Pre-String", "Use Post-String"; Param42= "Not in Poll","Data in Poll"; Param43= "Ignore this instance","Search receive string"; Param44= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 5 $ $_______________________________________________________________$ Param47= "Use Data", "Use Pre-String", "Use Post-String"; Param51= "Not in Poll","Data in Poll"; Param52= "Ignore this instance","Search receive string"; Param53= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 6 $ $_______________________________________________________________$ Param56= "Use Data", "Use Pre-String", "Use Post-String"; Param60= "Not in Poll","Data in Poll"; Param61= "Ignore this instance","Search receive string"; Param62= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 7 $ $_______________________________________________________________$ Param65= "Use Data", "Use Pre-String", "Use Post-String"; Param69= "Not in Poll","Data in Poll"; Param70= "Ignore this instance","Search receive string"; Param71= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Receive Object Class 65(0x41) $ $ Instance 8 $ $_______________________________________________________________$ Param74= "Use Data", "Use Pre-String", "Use Post-String"; Param78= "Not in Poll","Data in Poll"; Param79= "Ignore this instance","Search receive string"; Param80= "Sync Off","Sync On"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 1 $ $_______________________________________________________________$ Param83= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param89= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 2 $ $_______________________________________________________________$ Param92= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param98= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 3 $ $_______________________________________________________________$ Param101= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param107= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 4 $ $_______________________________________________________________$ Param110= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param116= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 5 $ $_______________________________________________________________$ Param119= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param125= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 6 $ $_______________________________________________________________$ Param128= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param134= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 7 $ $_______________________________________________________________$ Param137= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param143= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Serial Transmit Object Class 66(0x42) $ $ Instance 8 $ $_______________________________________________________________$ Param146= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param152= "Not in Poll Command", "In Poll Command"; $_______________________________________________________________$ $ Extended Parameter Enumeration $ $ $ $_______________________________________________________________$ Param153= "Rx Fifo Overrun", "Rx Parity Error", "", "", "Tx Fifo Overrun", "Tx Parity Error"; [Groups] Group1="Serial Stream Object", 11,1,2,3,4,5,6,7,8,153,154,155; Group2="Rx Inst 1",11,9,10,11,12,13,14,15,16,17,156,164; Group3="Rx Inst 2",11,18,19,20,21,22,23,24,25,26,157,165; Group4="Rx Inst 3",11,27,28,29,30,31,32,33,34,35,158,166; Group5="Rx Inst 4",11,36,37,38,39,40,41,42,43,44,159,167; Group6="Rx Inst 5",11,45,46,47,48,49,50,51,52,53,160,168; Group7="Rx Inst 6",11,54,55,56,57,58,59,60,61,62,161,169; Group8="Rx Inst 7",11,63,64,65,66,67,68,69,70,71,162,170; Group9="Rx Inst 8",11,72,73,74,75,76,77,78,79,80,163,171; Group10="Tx Inst 1",9,81,82,83,84,85,86,87,88,89; Group11="Tx Inst 2",9,90,91,92,93,94,95,96,97,98; Group12="Tx Inst 3",9,99,100,101,102,103,104,105,106,107; Group13="Tx Inst 4",9,108,109,110,111,112,113,114,115,116; Group14="Tx Inst 5",9,117,118,119,120,121,122,123,124,125; Group15="Tx Inst 6",9,126,127,128,129,130,131,132,133,134; Group16="Tx Inst 7",9,135,136,137,138,139,140,141,142,143; Group17="Tx Inst 8",9,144,145,146,147,148,149,150,151,152;