$ DeviceNet Electronic Data Sheet $ Electronic Data Sheet generated using SST EDS Editor $ Copyright (C) 1998 S-S Technologies Inc. [File] DescText = "DeviceNet Network"; CreateDate = 11-08-1999; CreateTime = 04:31:48; ModDate = 06-27-11; ModTime = 14:32:56; Revision = 3.1; [Device] VendCode = 59; VendName = "D.I.P. Inc."; ProdType = 12; ProdTypeStr = "Communications Adapter"; ProdCode = 5872; MajRev = 3; MinRev = 1; ProdName = "AS01367G-01"; Catalog = "Adv. RS485 Gateway"; [IO_Info] Default = 0x0001; PollInfo = 0x0001, 0, 0; [ParamClass] MaxInst = 171; Descriptor = 0x0009; CfgAssembly = 0; [Params] Param1= 0, 6, "20 40 24 01 30 03", 0x01, 9, 4, "Baud Rate", "bits per second", "Baud Rate for RS232 channel \nCommon Baud Rates\n\n\t300\n\t600\n\t1200\n\t2400\n\t4800\n\t9600\n\t19200\n\t38400\n\t57600", 0, 57600, 19200, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param2= 0, 6, "20 40 24 01 30 04", 0x03, 8, 1, "Data Bits", "", "Specifies the number of Data bits (7 or 8)", 7, 8, 8, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param3= 0, 6, "20 40 24 01 30 05", 0x03, 8, 1, "Parity", "", "Parity on RS232 channel.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param4= 0, 6, "20 40 24 01 30 06", 0x01, 8, 1, "Stop Bits", "", "Number of Stop Bits terminating a serial character", 1, 2, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param5= 0, 6, "20 40 24 01 30 07", 0x03, 8, 1, "Flow Control", "", "Flow Control on RS232 channel.", 0, 2, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param6= 0, 6, "20 40 24 01 30 0A", 0x03, 24, 1, "Delimiter Mode", "", "Bit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tReserved\tReserved\tLength\tTimeout\tList", 0, 6, 4, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param7= 0, 6, "20 40 24 01 30 0D", 0x01, 8, 1, "Timeout", "ms", "Sets max timeout in milliseconds between bytes that the unit uses to determine when a packet is complete", 0, 255, 255, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param8= 0, 6, "20 40 24 01 30 0E", 0x01, 8, 1, "Packet Length", "bytes", "Specifies the number of bytes to wait for before determining packet is complete.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param9= 0, 6, "20 41 24 01 30 04", 0x30, 4, 1, "(Rx Inst-1) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param10= 0, 6, "20 41 24 01 30 05", 0x01, 4, 1, "(Rx Inst-1) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param11= 0, 6, "20 41 24 01 30 06", 0x03, 24, 1, "(Rx Inst-1) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param12= 0, 6, "20 41 24 01 30 09", 0x01, 8, 1, "(Rx Inst-1) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list)..", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param13= 0, 6, "20 41 24 01 30 0A", 0x01, 8, 1, "(Rx Inst-1) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param14= 0, 6, "20 41 24 01 30 0D", 0x01, 8, 1, "(Rx Inst-1) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param15= 0, 6, "20 41 24 01 30 F", 0x03, 4, 1, "(Rx Inst-1) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param16= 0, 6, "20 41 24 01 30 10", 0x03, 4, 1, "(Rx Inst-1) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param17= 0, 6, "20 41 24 01 30 11", 0x03, 4, 1, "(Rx Inst-1) Sync Enabled", "", "When set the unit will not respond with new data until thevalue in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param18= 0, 6, "20 41 24 02 30 04", 0x30, 4, 1, "(Rx Inst-2) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param19= 0, 6, "20 41 24 02 30 05", 0x01, 4, 1, "(Rx Inst-2) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param20= 0, 6, "20 41 24 02 30 06", 0x03, 24, 1, "(Rx Inst-2) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param21= 0, 6, "20 41 24 02 30 09", 0x01, 8, 1, "(Rx Inst-2) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list)..", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param22= 0, 6, "20 41 24 02 30 0A", 0x01, 8, 1, "(Rx Inst-2) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param23= 0, 6, "20 41 24 02 30 0D", 0x01, 8, 1, "(Rx Inst-2) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param24= 0, 6, "20 41 24 02 30 F", 0x03, 4, 1, "(Rx Inst-2) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param25= 0, 6, "20 41 24 02 30 10", 0x03, 4, 1, "(Rx Inst-2) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param26= 0, 6, "20 41 24 02 30 11", 0x03, 4, 1, "(Rx Inst-2) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param27= 0, 6, "20 41 24 03 30 04", 0x30, 4, 1, "(Rx Inst-3) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param28= 0, 6, "20 41 24 03 30 05", 0x01, 4, 1, "(Rx Inst-3) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param29= 0, 6, "20 41 24 03 30 06", 0x03, 24, 1, "(Rx Inst-3) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param30= 0, 6, "20 41 24 03 30 09", 0x01, 8, 1, "(Rx Inst-3) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param31= 0, 6, "20 41 24 03 30 0A", 0x01, 8, 1, "(Rx Inst-3) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param32= 0, 6, "20 41 24 03 30 0D", 0x01, 8, 1, "(Rx Inst-3) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param33= 0, 6, "20 41 24 03 30 F", 0x03, 4, 1, "(Rx Inst-3) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param34= 0, 6, "20 41 24 03 30 10", 0x03, 4, 1, "(Rx Inst-3) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param35= 0, 6, "20 41 24 03 30 11", 0x03, 4, 1, "(Rx Inst-3) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param36= 0, 6, "20 41 24 04 30 04", 0x30, 4, 1, "(Rx Inst-4) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param37= 0, 6, "20 41 24 04 30 05", 0x01, 4, 1, "(Rx Inst-4) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param38= 0, 6, "20 41 24 04 30 06", 0x03, 24, 1, "(Rx Inst-4) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param39= 0, 6, "20 41 24 04 30 09", 0x01, 8, 1, "(Rx Inst-4) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2\n INT = 0xC3\n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param40= 0, 6, "20 41 24 04 30 0A", 0x01, 8, 1, "(Rx Inst-4) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param41= 0, 6, "20 41 24 04 30 0D", 0x01, 8, 1, "(Rx Inst-4) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param42= 0, 6, "20 41 24 04 30 F", 0x03, 4, 1, "(Rx Inst-4) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 0, 0, 0, 0, 0, 0, 0; Param43= 0, 6, "20 41 24 04 30 10", 0x03, 4, 1, "(Rx Inst-4) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param44= 0, 6, "20 41 24 04 30 11", 0x03, 4, 1, "(Rx Inst-4) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param45= 0, 6, "20 41 24 05 30 04", 0x30, 4, 1, "(Rx Inst-5) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param46= 0, 6, "20 41 24 05 30 05", 0x01, 4, 1, "(Rx Inst-5) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param47= 0, 6, "20 41 24 05 30 06", 0x03, 24, 1, "(Rx Inst-5) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param48= 0, 6, "20 41 24 05 30 09", 0x01, 8, 1, "(Rx Inst-5) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param49= 0, 6, "20 41 24 05 30 0A", 0x01, 8, 1, "(Rx Inst-5) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param50= 0, 6, "20 41 24 05 30 0D", 0x01, 8, 1, "(Rx Inst-5) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param51= 0, 6, "20 41 24 05 30 F", 0x03, 4, 1, "(Rx Inst-5) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param52= 0, 6, "20 41 24 05 30 10", 0x03, 4, 1, "(Rx Inst-5) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param53= 0, 6, "20 41 24 05 30 11", 0x03, 4, 1, "(Rx Inst-5) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param54= 0, 6, "20 41 24 06 30 04", 0x30, 4, 1, "(Rx Inst-6) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param55= 0, 6, "20 41 24 06 30 05", 0x01, 4, 1, "(Rx Inst-6) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param56= 0, 6, "20 41 24 06 30 06", 0x03, 24, 1, "(Rx Inst-6) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param57= 0, 6, "20 41 24 06 30 09", 0x01, 8, 1, "(Rx Inst-6) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param58= 0, 6, "20 41 24 06 30 0A", 0x01, 8, 1, "(Rx Inst-6) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param59= 0, 6, "20 41 24 06 30 0D", 0x01, 8, 1, "(Rx Inst-6) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param60= 0, 6, "20 41 24 06 30 F", 0x03, 4, 1, "(Rx Inst-6) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param61= 0, 6, "20 41 24 06 30 10", 0x03, 4, 1, "(Rx Inst-6) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param62= 0, 6, "20 41 24 06 30 11", 0x03, 4, 1, "(Rx Inst-6) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param63= 0, 6, "20 41 24 07 30 04", 0x30, 4, 1, "(Rx Inst-7) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param64= 0, 6, "20 41 24 07 30 05", 0x01, 4, 1, "(Rx Inst-7) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param65= 0, 6, "20 41 24 07 30 06", 0x03, 24, 1, "(Rx Inst-7) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param66= 0, 6, "20 41 24 07 30 09", 0x01, 8, 1, "(Rx Inst-7) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String) \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param67= 0, 6, "20 41 24 07 30 0A", 0x01, 8, 1, "(Rx Inst-7) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param68= 0, 6, "20 41 24 07 30 0D", 0x01, 8, 1, "(Rx Inst-7) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param69= 0, 6, "20 41 24 07 30 F", 0x03, 4, 1, "(Rx Inst-7) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param70= 0, 6, "20 41 24 07 30 10", 0x03, 4, 1, "(Rx Inst-7) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param71= 0, 6, "20 41 24 07 30 11", 0x03, 4, 1, "(Rx Inst-7) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param72= 0, 6, "20 41 24 08 30 04", 0x30, 4, 1, "(Rx Inst-8) Receive Toggle", "", "Toggles when new data has been received.\n Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param73= 0, 6, "20 41 24 08 30 05", 0x01, 4, 1, "(Rx Inst-8) Receive Acknowledge", "", "This value is to match the value of the Receive Toggle bit to release new data.Maps to bit 0 of the [RxToggle1-8] handshaking byte in the poll response.\nOnly used when sync is enabled.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param74= 0, 6, "20 41 24 08 30 06", 0x03, 24, 1, "(Rx Inst-8) Receive Mode", "", "Used to select what receive object looks for in a packet.\n Bits 7-3 Reserved, Bit 2 - Use Post, Bit 1 - Use Pre, Bit 0 - Use Data ", 0, 7, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param75= 0, 6, "20 41 24 08 30 09", 0x01, 8, 1, "(Rx Inst-8) Data Type", "", "Selects DeviceNet Data type the data extracted by this instance will be converted to.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n Default is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param76= 0, 6, "20 41 24 08 30 0A", 0x01, 8, 1, "(Rx Inst-8) Data Size", "bytes", "Sets the size of the DeviceNet data returned by the unit.\nSettable only if data type is SHORT_STRING. For the SHORT_STING type, Data Size = 1 + Number of characters to receive. \n Settable only when poll connection is not established (Device should be removed from the scanlist.)", 1, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param77= 0, 6, "20 41 24 08 30 0D", 0x01, 8, 1, "(Rx Inst-8) Conversion Type", "", "Specifies whether integers are converted from hex or decimal.\nAcceptable values are 'd' or 'x'.", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param78= 0, 6, "20 41 24 08 30 F", 0x03, 4, 1, "(Rx Inst-8) Data in Poll Response", "", "If set, adds receive data to poll response.\n Settable only when poll connection is not established. \n(Device should be removed from the scanlist.)", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param79= 0, 6, "20 41 24 08 30 10", 0x03, 4, 1, "(Rx Inst-8) Enabled", "", "When set the unit tries to process a portion of the recieved packet to extract a data field that satisfies the 'Recieve Mode' attribute. When clear this instance is ignored.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param80= 0, 6, "20 41 24 08 30 11", 0x03, 4, 1, "(Rx Inst-8) Sync Enabled", "", "When set, the unit will not respond with new data until the value in the Receive Acknowledge attribute matches the value in the receive Toggle attribute.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param81= 0, 6, "20 42 24 01 30 04", 0x01, 4, 1, "(Tx Inst-1) Transmit Toggle", "", "Toggled to transmit new Instance 1 data. Mapped to bit 0 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param82= 0, 6, "20 42 24 01 30 05", 0x30, 4, 1, "(Tx Inst-1) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param83= 0, 6, "20 42 24 01 30 06", 0x03, 24, 1, "(Tx Inst-1) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param84= 0, 6, "20 42 24 01 30 09", 0x01, 8, 1, "(Tx Inst-1) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param85= 0, 6, "20 42 24 01 30 0A", 0x01, 8, 1, "(Tx Inst-1) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param86= 0, 6, "20 42 24 01 30 0B", 0x01, 8, 1, "(Tx Inst-1) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param87= 0, 6, "20 42 24 01 30 0C", 0x01, 8, 1, "(Tx Inst-1) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param88= 0, 6, "20 42 24 01 30 0D", 0x01, 8, 1, "(Tx Inst-1) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param89= 0, 6, "20 42 24 01 30 0F", 0x03, 4, 1, "(Tx Inst-1) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param90= 0, 6, "20 42 24 02 30 04", 0x01, 4, 1, "(Tx Inst-2) Transmit Toggle", "", "Toggled to transmit new Instance 2 data. Mapped to bit 1 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param91= 0, 6, "20 42 24 02 30 05", 0x30, 4, 1, "(Tx Inst-2) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param92= 0, 6, "20 42 24 02 30 06", 0x03, 24, 1, "(Tx Inst-2) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param93= 0, 6, "20 42 24 02 30 09", 0x01, 8, 1, "(Tx Inst-2) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param94= 0, 6, "20 42 24 02 30 0A", 0x01, 8, 1, "(Tx Inst-2) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param95= 0, 6, "20 42 24 02 30 0B", 0x01, 8, 1, "(Tx Inst-2) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param96= 0, 6, "20 42 24 02 30 0C", 0x01, 8, 1, "(Tx Inst-2) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param97= 0, 6, "20 42 24 02 30 0D", 0x01, 8, 1, "(Tx Inst-2) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param98= 0, 6, "20 42 24 02 30 0F", 0x03, 4, 1, "(Tx Inst-2) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param99= 0, 6, "20 42 24 03 30 04", 0x01, 4, 1, "(Tx Inst-3) Transmit Toggle", "", "Toggled to transmit new Instance 3 data. Mapped to bit 2 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param100= 0, 6, "20 42 24 03 30 05", 0x30, 4, 1, "(Tx Inst-3) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param101= 0, 6, "20 42 24 03 30 06", 0x03, 24, 1, "(Tx Inst-3) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param102= 0, 6, "20 42 24 03 30 09", 0x01, 8, 1, "(Tx Inst-3) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param103= 0, 6, "20 42 24 03 30 0A", 0x01, 8, 1, "(Tx Inst-3) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param104= 0, 6, "20 42 24 03 30 0B", 0x01, 8, 1, "(Tx Inst-3) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param105= 0, 6, "20 42 24 03 30 0C", 0x01, 8, 1, "(Tx Inst-3) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param106= 0, 6, "20 42 24 03 30 0D", 0x01, 8, 1, "(Tx Inst-3) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param107= 0, 6, "20 42 24 03 30 0F", 0x03, 4, 1, "(Tx Inst-3) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param108= 0, 6, "20 42 24 04 30 04", 0x01, 4, 1, "(Tx Inst-4) Transmit Toggle", "", "Toggled to transmit new Instance 4 data. Mapped to bit 3 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param109= 0, 6, "20 42 24 04 30 05", 0x30, 4, 1, "(Tx Inst-4) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param110= 0, 6, "20 42 24 04 30 06", 0x03, 24, 1, "(Tx Inst-4) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param111= 0, 6, "20 42 24 04 30 09", 0x01, 8, 1, "(Tx Inst-4) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param112= 0, 6, "20 42 24 04 30 0A", 0x01, 8, 1, "(Tx Inst-4) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param113= 0, 6, "20 42 24 04 30 0B", 0x01, 8, 1, "(Tx Inst-4) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param114= 0, 6, "20 42 24 04 30 0C", 0x01, 8, 1, "(Tx Inst-4) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param115= 0, 6, "20 42 24 04 30 0D", 0x01, 8, 1, "(Tx Inst-4) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param116= 0, 6, "20 42 24 04 30 0F", 0x03, 4, 1, "(Tx Inst-4) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param117= 0, 6, "20 42 24 05 30 04", 0x01, 4, 1, "(Tx Inst-5) Transmit Toggle", "", "Toggled to transmit new Instance 5 data. Mapped to bit 4 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param118= 0, 6, "20 42 24 05 30 05", 0x30, 4, 1, "(Tx Inst-5) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param119= 0, 6, "20 42 24 05 30 06", 0x03, 24, 1, "(Tx Inst-5) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param120= 0, 6, "20 42 24 05 30 09", 0x01, 8, 1, "(Tx Inst-5) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param121= 0, 6, "20 42 24 05 30 0A", 0x01, 8, 1, "(Tx Inst-5) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param122= 0, 6, "20 42 24 05 30 0B", 0x01, 8, 1, "(Tx Inst-5) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param123= 0, 6, "20 42 24 05 30 0C", 0x01, 8, 1, "(Tx Inst-5) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param124= 0, 6, "20 42 24 05 30 0D", 0x01, 8, 1, "(Tx Inst-5) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param125= 0, 6, "20 42 24 05 30 0F", 0x03, 4, 1, "(Tx Inst-5) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param126= 0, 6, "20 42 24 06 30 04", 0x01, 4, 1, "(Tx Inst-6) Transmit Toggle", "", "Toggled to transmit new Instance 6 data. Mapped to bit 5 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param127= 0, 6, "20 42 24 06 30 05", 0x30, 4, 1, "(Tx Inst-6) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param128= 0, 6, "20 42 24 06 30 06", 0x03, 24, 1, "(Tx Inst-6) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param129= 0, 6, "20 42 24 06 30 09", 0x01, 8, 1, "(Tx Inst-6) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param130= 0, 6, "20 42 24 06 30 0A", 0x01, 8, 1, "(Tx Inst-6) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param131= 0, 6, "20 42 24 06 30 0B", 0x01, 8, 1, "(Tx Inst-6) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param132= 0, 6, "20 42 24 06 30 0C", 0x01, 8, 1, "(Tx Inst-6) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param133= 0, 6, "20 42 24 06 30 0D", 0x01, 8, 1, "(Tx Inst-6) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param134= 0, 6, "20 42 24 06 30 0F", 0x03, 4, 1, "(Tx Inst-6) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param135= 0, 6, "20 42 24 07 30 04", 0x01, 4, 1, "(Tx Inst-7) Transmit Toggle", "", "Toggled to transmit new Instance 7 data. Mapped to bit 6 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param136= 0, 6, "20 42 24 07 30 05", 0x30, 4, 1, "(Tx Inst-7) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param137= 0, 6, "20 42 24 07 30 06", 0x03, 24, 1, "(Tx Inst-7) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param138= 0, 6, "20 42 24 07 30 09", 0x01, 8, 1, "(Tx Inst-7) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param139= 0, 6, "20 42 24 07 30 0A", 0x01, 8, 1, "(Tx Inst-7) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param140= 0, 6, "20 42 24 07 30 0B", 0x01, 8, 1, "(Tx Inst-7) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param141= 0, 6, "20 42 24 07 30 0C", 0x01, 8, 1, "(Tx Inst-7) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param142= 0, 6, "20 42 24 07 30 0D", 0x01, 8, 1, "(Tx Inst-7) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param143= 0, 6, "20 42 24 07 30 0F", 0x03, 4, 1, "(Tx Inst-7) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param144= 0, 6, "20 42 24 08 30 04", 0x01, 4, 1, "(Tx Inst-8) Transmit Toggle", "", "Toggled to transmit new Instance 8 data. Mapped to bit 7 of the [TxToggle1-8] byte in the poll command.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param145= 0, 6, "20 42 24 08 30 05", 0x30, 4, 1, "(Tx Inst-8) Transmit Acknowledge", "", "Toggles when transmit from previous poll command is complete.", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param146= 0, 6, "20 42 24 08 30 06", 0x03, 24, 1, "(Tx Inst-8) Transmit Mode", "", "Sets transmit mode to determine the order String1, String2 and data are transmitted.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\n Reserved\tReserved\tReserved\tString2\tString1\tString2\tString1\tData\n\t\t\tAfter\tAfter\tBefore\tBefore", 0, 0x1F, 0x01, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param147= 0, 6, "20 42 24 08 30 09", 0x01, 8, 1, "(Tx Inst-8) Data Type ", "", "Selects DeviceNet Data type of the data being transmitted.\n\n SINT = 0xC2 \n INT = 0xC3 \n USINT = 0xC6 \n UINT = C7 \n REAL = 0xCA \n SHORT_STRING = 0xDA \n\nDefault is 0xDA (Short_String). \n\nSettable when poll connection is not established (CDN366 must be taken out of the scan list).", 0xC2, 0xDA, 0xDA, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param148= 0, 6, "20 42 24 08 30 0A", 0x01, 8, 1, "(Tx Inst-8) Data Size", "", "Settable only when data type is SHORT_STRING and when the poll connection is not established (CDN366 must be taken out of the scan list). \n For the SHORT_STING type, Data Size = 1 + Number of characters to transmit", 0, 255, 17, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param149= 0, 6, "20 42 24 08 30 0B", 0x01, 8, 1, "(Tx Inst-8) Width ", "", "Sets the field width for the instance data.", 0, 255, 16, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param150= 0, 6, "20 42 24 08 30 0C", 0x01, 8, 1, "(Tx Inst-8) Precision ", "", "Sets the number of decimal places to be transmited for the REAL data type.\n Used only for REAL data type.", 0, 4, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param151= 0, 6, "20 42 24 08 30 0D", 0x01, 8, 1, "(Tx Inst-8) Conversion Type", "", "Sets conversion type and zero padding for numeric data.\n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nLeading\tTrailing\tReserved\tReserved\tReserved\tReserved\tReserved\tHex\nZeros\tZeros", 0, 0xFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param152= 0, 6, "20 42 24 08 30 0F", 0x03, 4, 1, "(Tx Inst-8) Data in Poll Command", "", "Set to accept data in poll commmand.\n Settable when poll connection is not established (CDN366 must not be in the scan list).", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param153= 0, 6, "20 40 24 01 30 0F", 0x23, 24, 1, "Serial Status", "", "Indicates the occurance of a parity error or fifo overrun. Setting this value resets the error status. \n\nBit 7\tBit 6\tBit 5\tBit 4\tBit 3\tBit 2\tBit 1\tBit 0\nReserved\tReserved\tTx Parity\tTx Fifo\tReserved\tReserved\tRX Parity\tRx Fifo\n\t\tError\tOverrun\t\tError\tOverrun", 0, 255, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param154= 0, 6, "20 40 24 01 30 14", 0x30, 2, 2, "Poll Produce Size", "", "The size of the poll response once a polled connection is established", 0, 0xFFFF, 19, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param155= 0, 6, "20 40 24 01 30 15", 0x30, 2, 2, "Poll Consume Size", "", "The size of the poll command once a polled connection is established", 0, 0xFFFF, 19, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param156= 0, 6, "20 41 24 01 30 0b", 0x01, 8, 1, "(Rx Inst-1) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param157= 0, 6, "20 41 24 02 30 0b", 0x01, 8, 1, "(Rx Inst-2) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param158= 0, 6, "20 41 24 03 30 0b", 0x01, 8, 1, "(Rx Inst-3) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param159= 0, 6, "20 41 24 04 30 0b", 0x01, 8, 1, "(Rx Inst-4) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param160= 0, 6, "20 41 24 05 30 0b", 0x01, 8, 1, "(Rx Inst-5) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param161= 0, 6, "20 41 24 06 30 0b", 0x01, 8, 1, "(Rx Inst-6) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param162= 0, 6, "20 41 24 07 30 0b", 0x01, 8, 1, "(Rx Inst-7) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param163= 0, 6, "20 41 24 08 30 0b", 0x01, 8, 1, "(Rx Inst-8) Width", "", "The maximum number of recieved rs232 bytes the CDN366 will convert for this instance. Any data recieved past width will be truncated. ", 1, 0xFF, 1, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param164= 0, 6, "20 41 24 01 30 0e", 0x01, 8, 1, "(Rx Inst-1) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param165= 0, 6, "20 41 24 02 30 0e", 0x01, 8, 1, "(Rx Inst-2) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param166= 0, 6, "20 41 24 03 30 0e", 0x01, 8, 1, "(Rx Inst-3) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param167= 0, 6, "20 41 24 04 30 0e", 0x01, 8, 1, "(Rx Inst-4) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param168= 0, 6, "20 41 24 05 30 0e", 0x01, 8, 1, "(Rx Inst-5) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param169= 0, 6, "20 41 24 06 30 0e", 0x01, 8, 1, "(Rx Inst-6) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param170= 0, 6, "20 41 24 07 30 0e", 0x01, 8, 1, "(Rx Inst-7) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; Param171= 0, 6, "20 41 24 08 30 0e", 0x01, 8, 1, "(Rx Inst-8) Padding Char.", "", "For the Short_String data type, if the extracted serial data is less than DATA_SIZE bytes, the data will be left justified with the ASCII value of the Padding Character attribute in the DeviceNet poll response.", 0, 0xFF, 00, 1, 1, 1, 0, 0, 0, 0, 0, 0; [EnumPar] Param2= "7 Data Bits", "8 Data Bits"; Param3= "None", "Odd", "Even", "Mark", "Space"; Param5= "None", "XON/XOFF", "CTS/RTS"; Param6= "List", "Timeout", "Length"; Param11= "Use Data", "Use Pre-String", "Use Post-String"; Param15= "Not in Poll", "Data in Poll"; Param16= "Ignore this instance", "Search receive string"; Param17= "Sync Off", "Sync On"; Param20= "Use Data", "Use Pre-String", "Use Post-String"; Param24= "Not in Poll", "Data in Poll"; Param25= "Ignore this instance", "Search receive string"; Param26= "Sync Off", "Sync On"; Param29= "Use Data", "Use Pre-String", "Use Post-String"; Param33= "Not in Poll", "Data in Poll"; Param34= "Ignore this instance", "Search receive string"; Param35= "Sync Off", "Sync On"; Param38= "Use Data", "Use Pre-String", "Use Post-String"; Param42= "Not in Poll", "Data in Poll"; Param43= "Ignore this instance", "Search receive string"; Param44= "Sync Off", "Sync On"; Param47= "Use Data", "Use Pre-String", "Use Post-String"; Param51= "Not in Poll", "Data in Poll"; Param52= "Ignore this instance", "Search receive string"; Param53= "Sync Off", "Sync On"; Param56= "Use Data", "Use Pre-String", "Use Post-String"; Param60= "Not in Poll", "Data in Poll"; Param61= "Ignore this instance", "Search receive string"; Param62= "Sync Off", "Sync On"; Param65= "Use Data", "Use Pre-String", "Use Post-String"; Param69= "Not in Poll", "Data in Poll"; Param70= "Ignore this instance", "Search receive string"; Param71= "Sync Off", "Sync On"; Param74= "Use Data", "Use Pre-String", "Use Post-String"; Param78= "Not in Poll", "Data in Poll"; Param79= "Ignore this instance", "Search receive string"; Param80= "Sync Off", "Sync On"; Param83= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param89= "Not in Poll Command", "In Poll Command"; Param92= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param98= "Not in Poll Command", "In Poll Command"; Param101= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param107= "Not in Poll Command", "In Poll Command"; Param110= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param116= "Not in Poll Command", "In Poll Command"; Param119= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param125= "Not in Poll Command", "In Poll Command"; Param128= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param134= "Not in Poll Command", "In Poll Command"; Param137= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param143= "Not in Poll Command", "In Poll Command"; Param146= "Data", "String1 Before", "String2 Before", "String1 After", "String2 After"; Param152= "Not in Poll Command", "In Poll Command"; Param153= "Rx Fifo Overrun", "Rx Parity Error", "", "", "Tx Fifo Overrun", "Tx Parity Error"; [Groups] Group1= "Serial Stream Object", 11, 1, 2, 3, 4, 5, 6, 7, 8, 153, 154, 155; Group2= "Rx Inst 1", 11, 9, 10, 11, 12, 13, 14, 15, 16, 17, 156, 164; Group3= "Rx Inst 2", 11, 18, 19, 20, 21, 22, 23, 24, 25, 26, 157, 165; Group4= "Rx Inst 3", 11, 27, 28, 29, 30, 31, 32, 33, 34, 35, 158, 166; Group5= "Rx Inst 4", 11, 36, 37, 38, 39, 40, 41, 42, 43, 44, 159, 167; Group6= "Rx Inst 5", 11, 45, 46, 47, 48, 49, 50, 51, 52, 53, 160, 168; Group7= "Rx Inst 6", 11, 54, 55, 56, 57, 58, 59, 60, 61, 62, 161, 169; Group8= "Rx Inst 7", 11, 63, 64, 65, 66, 67, 68, 69, 70, 71, 162, 170; Group9= "Rx Inst 8", 11, 72, 73, 74, 75, 76, 77, 78, 79, 80, 163, 171; Group10= "Tx Inst 1", 9, 81, 82, 83, 84, 85, 86, 87, 88, 89; Group11= "Tx Inst 2", 9, 90, 91, 92, 93, 94, 95, 96, 97, 98; Group12= "Tx Inst 3", 9, 99, 100, 101, 102, 103, 104, 105, 106, 107; Group13= "Tx Inst 4", 9, 108, 109, 110, 111, 112, 113, 114, 115, 116; Group14= "Tx Inst 5", 9, 117, 118, 119, 120, 121, 122, 123, 124, 125; Group15= "Tx Inst 6", 9, 126, 127, 128, 129, 130, 131, 132, 133, 134; Group16= "Tx Inst 7", 9, 135, 136, 137, 138, 139, 140, 141, 142, 143; Group17= "Tx Inst 8", 9, 144, 145, 146, 147, 148, 149, 150, 151, 152;