Compare Model Drawings, CAD & Specs Full Scale Pressure Analog Output Fitting Type Electrical Connector Availability Price
Pressure Transducer, 100 psia, Single-end, 0-10 VDC, 0.25 in. Tube, LDM-C, 15-pin HD
$1,325
3 Weeks
AA07A12PBB2GT1 Pressure Transducer, 100 psia, Single-end, 0-10 VDC, 0.25 in. Tube, LDM-C, 15-pin HD 100 psia 0-10 VDC 0.25 in. weld stub 15-pin high density type D
3 Weeks
$1,325
Pressure Transmitter, 100 psia, Single-end, 4-20 mA, 4 VCR Male, Flying Leads
$1,200
AA07A12PCB4GF4 Pressure Transmitter, 100 psia, Single-end, 4-20 mA, 4 VCR Male, Flying Leads 100 psia 4-20 mA 4 VCR male 6 ft. flying leads $1,200
Pressure Transducer, 100 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead
$955
AA07A12PCD2GA1 Pressure Transducer, 100 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead 100 psia 0-10 VDC 4 VCR female 9-pin Type D on 9 in. flying lead $955
Pressure Transducer, 1000 psia, Single-end, 0-10 VDC, 4 VCR Male, DB9 on 9 in. Flying Lead
$950
AA07A13PCB2GA1 Pressure Transducer, 1000 psia, Single-end, 0-10 VDC, 4 VCR Male, DB9 on 9 in. Flying Lead 1000 psia 0-10 VDC 4 VCR male 9-pin Type D on 9 in. flying lead $950
Pressure Transducer, 1000 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead
$955
AA07A13PCD2GA1 Pressure Transducer, 1000 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead 1000 psia 0-10 VDC 4 VCR female 9-pin Type D on 9 in. flying lead $955
Pressure Transducer, 1000 Torr, Single-end, 0-5 VDC, 4 VCR Male, DB9 on 9 in. Flying Lead
$925
AA07A13TCB3GA1 Pressure Transducer, 1000 Torr, Single-end, 0-5 VDC, 4 VCR Male, DB9 on 9 in. Flying Lead 1000 Torr 0-5 VDC 4 VCR male 9-pin Type D on 9 in. flying lead $925
Pressure Transducer, 1000 Torr, Single-end, 0-10 VDC, 4 VCR Female, 15-pin HD on 9 in. Flying Lead
$925
AA07A13TCD2GC1 Pressure Transducer, 1000 Torr, Single-end, 0-10 VDC, 4 VCR Female, 15-pin HD on 9 in. Flying Lead 1000 Torr 0-10 VDC 4 VCR female 15-pin high density type D on 9 in. flying lead $925
Pressure Transmitter, 3000 psia, Single-end, 4-20 mA, 0.25 in. Weld T, Flying Leads
$1,275
AA07A33PBD4GL4 Pressure Transmitter, 3000 psia, Single-end, 4-20 mA, 0.25 in. Weld T, Flying Leads 3000 psia 4-20 mA 0.25 in. butt weld T 10 ft. flying leads $1,275
Pressure Transducer, 3000 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead
$955
3 Weeks
AA07A33PCD2GA1 Pressure Transducer, 3000 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead 3000 psia 0-10 VDC 4 VCR female 9-pin Type D on 9 in. flying lead
3 Weeks
$955
Pressure Transducer, 250 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead
$955
3 Weeks
AA07ARDPCD2GA1 Pressure Transducer, 250 psia, Single-end, 0-10 VDC, 4 VCR Female, DB9 on 9 in. Flying Lead 250 psia 0-10 VDC 4 VCR female 9-pin Type D on 9 in. flying lead
3 Weeks
$955
Pressure Transmitter, 250 psia, Single-end, 4-20 mA, 4 VCR Male, Bendix 4-pin
$975
AA07ARDPCD4GD1 Pressure Transmitter, 250 psia, Single-end, 4-20 mA, 4 VCR Male, Bendix 4-pin 250 psia 4-20 mA 4 VCR female 4-pin Bendix $975

Product Options

Description
  AA07A AA07A Micro-Baratron® Pressure Transducer, Single-end, See Available Product Options

Specifications

  • Configuration
    Single-ended
  • Measurement Type
    Absolute
  • Accuracy
    1.0% of Reading
  • Zero Temperature Coefficient
    0.02% of Full Scale/°C, 50 psia to 3000 psia
    0.04% of Full Scale/°C, 1000 Torr
  • Span Temperature Coefficient
    0.04% of Reading/°C, 50 psia to 3000 psia
    0.08% of Reading/°C, 1000 Torr
  • Overpressure Limit
    1.5 x Full Scale for ranges from 1000 Torr to 500 psi
    1.2 x Full Scale for ranges from 501 to 3000 psi
  • Burst Pressure
    10 x Full Scale for ranges from 1000 Torr to 500 psi
    5 x Full Scale for ranges from 501 to 3000 psi
  • Wetted Surfaces
    Incoloy®
  • Surface Finish
    ≤10 µin. Ra
  • Power Requirements
    13 to 32 VDC @ 10 mA max.
  • Operating Temperature Range
    0° to 50°C
  • Compliance
    CE

Features

Baratron® Capacitance Manometer Technology

Capacitance manometers are electro-mechanical gauges that can measure both pressure and vacuum. The capacitance gauge translates a pressure-modulated movement in a thin diaphragm into an electrical signal proportional to the pressure. The pressure sensor is the thin diaphragm that is exposed to the pressure or vacuum being measured via the inlet tube. An electrode is mounted in the reference cavity behind the diaphragm. Pressure differences between the process and the reference cavity deflect the diaphragm slightly, changing the distance between it and the electrode. Variations in this distance produce variations in the capacitance between the diaphragm and the electrode creating an electrical signal that is proportional to the pressure change. Since differences in the capacitance signal are produced by physical changes within the manometer and not by changes in the gas properties, pressure measurements by the capacitance manometer are independent of the composition of the gas being measured.

Gas independent absolute pressure measurement with a Baratron® capacitance manometer. Schematic shows the internal components and functional zones.

Percent of Reading Accuracy

Accuracy is specified as a percent of Reading, not Full Scale, as seen in some of the lower performance devices. Percent of Reading accuracy provides you with an even more accurate output signal in the lower scale of the pressure range, where it is needed most.

Ideally Suited for Ultrapure Gas Delivery Systems

The AA07A/AA08A transducers are ideally suited for use in delivery systems that feed ultrapure gases to critical process systems. Their wetted surfaces exposed to the gas stream have a finish of better than 5 µin Ra. These transducers exhibit superior dry-down characteristics, and contribute no particles above background. After manufacture and assembly, they are purged with ultraclean nitrogen prior to double bagging in a class 100 environment.

All Incoloy® Construction

The all-Incoloy® construction of the sensors in the AA07A/ AA08A allows for high overpressure tolerances that reduce errors due to line pressure spikes. High burst pressure ratings contribute to overall system safety. On existing gas cabinets and process systems, field replacement of common dial gauges or lower performance transducers is made easy due to the small size, industry standard endto-end lengths, and electrical interface choices of these transducers.

Optional Local Display

The optional local integrated display provides a digital readout of the line pressure at the transducer. The display, which is available on the 1000 Torr, 100 and 250 PSIA ranges with the 0-10 VDC output signal, provides a highlyvisible red LED display of the pressure and the units of measurement. The display can also be switched to show any of four different units (PSIA, Torr, bar, and kPa) without requiring recalibration or re-ranging of the transducer itself. It takes its power from the incoming transducer voltage, so no additional cables are required.

Need help?

Contact an Applications Specialist by sending us an email