Compare Description Drawings, CAD & Specs Full Scale Range Accuracy Fitting Type Availability Price
AA06A baratron absolute pressure sensor
$4,604
15 Weeks
0.1 mmHg 0.08% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,273
15 Weeks
0.1 mmHg 0.12% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,329
15 Weeks
1 mmHg 0.05% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,025
15 Weeks
1 mmHg 0.08% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$3,694
15 Weeks
1 mmHg 0.12% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,329
15 Weeks
10 mmHg 0.05% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,025
15 Weeks
10 mmHg 0.08% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$3,694
15 Weeks
10 mmHg 0.12% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,329
15 Weeks
100 mmHg 0.05% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,025
15 Weeks
100 mmHg 0.08% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$3,694
15 Weeks
100 mmHg 0.12% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,329
15 Weeks
1000 mmHg 0.05% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,025
15 Weeks
1000 mmHg 0.08% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$3,694
15 Weeks
1000 mmHg 0.12% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,466
15 Weeks
10000 mmHg 0.08% of Reading 4 VCR female
15 Weeks
AA06A baratron absolute pressure sensor
$4,135
15 Weeks
10000 mmHg 0.12% of Reading 4 VCR female
15 Weeks

Configuration Options

Description
AA06A baratron absolute pressure sensor AA06A Absolute Capacitance Manometer, High Accuracy, 0.1-1000 Torr, 4 VCR-F

Specifications

  • Measurement Type
    Absolute
  • Full Scale Pressure Ranges
    0.1, 1, 10, 100, 1000, 5000, 10000, 15000, 20000, or 25000 mmHg Full Scale
  • Fitting Type
    4 VCR female
  • Accuracy
    0.05%, 0.08%, or 0.12% of Reading ±zero/span coefficient
  • Resolution
    1 part in 106 Full Scale
  • Operating Temperature
    Temperature regulated at 45°C
  • Materials Exposed to Process Gases
    Inconel, Stainless Steel
  • Volume
    2.5 or 14 cc
  • Overpressure Limit
    40 - 45 psia or 125% of Full Scale
  • Compliance
    CE

Need help?